Handheld Signal Analyzer MSA500 Series

Handheld Signal Analyzer MSA500 Series

Welcome to a Biomedical Battery specialist of the Micronix Battery

The world's first handheld signal analyzer with REAL TIME plus SWEEP system!! 
With Fast Fourier Transform (FFT) and conventional sweep systems, each strong point of both systems is usable.

REAL TIME system enables unsteady signal measurement, time domain analysis and modulation analysis. SWEEP system enables measurement by wide span.

①Real time plus Sweep system
In real time system, the spectrum which occurs in an instant won't be missed. It is optimum for analyzing a noise and a transitional phenomenon. On the other hand, the sweep system is suitable for observing at wide frequency range. Various applications can be covered by making good use of advantage of each system.

②Sufficient analysis functions
In real time system, Spectrogram analysis and OverWrite analysis can be performed besides Spectrum analysis.

③Time domain analysis expanding analyzer capability
In real time system, time domain analyses such as power vs. time, frequency vs. time, phase vs. time, IQ vs. time and Q vs. I are possible.

④Fast OverWrite analysis of 720 frames/ sec
Since OverWrite analysis in real time system is processed at high speed as 720 frames/sec, even unnecessary spectrum which appears rarely isn't missed.

⑤Powerful trigger functions
In real time system, powerful trigger functions such as channel power trigger, power trigger, IF level trigger and external trigger can be used. With long time battery such as Micronix MB-300 Battery, Micronix MSA338 Battery, Micronix MSA358 Battery, TSI DustTrak II 8532 Battery, TSI DustTrak II 530EP Battery, TSI DustTrak DRX 8530 Battery, TSI DustTrak DRX 8534 Battery, Comen CM1200A Battery, Comen CM1200B Battery, GE Eagle Monitor 1008 Battery, GE Eagle Monitor 1009 Battery, TSI 9350 Battery

⑥Real time operation by 20MHz maximum span
Since a signal can be observed with maximum span of 20MHz in real time system, the modulation signals of almost all of wireless communications can be captured.

⑦Large memory of 16K frames and high speed USB communication
In real time system, data can be captured for a long time because the IQ memory is as large as 16K frames (64Mbytes). Moreover, IQ data can be transmitted to PC at speed of 19ms/frame.

⑧Average noise level -162dBm/Hz
The average noise level of -162dBm/Hz at [MSA538/538TG/538E] and -157dBm/Hz at [MSA558/558E] is achieved.
At span 20kHz in real time mode, it is -140dBm and -135dBm respectively.

⑨Compact and lightweight 1.8kg
The dimensions are as small as 162(W)×71(H)×265(D)mm, and the weight is only 1.8kg including the battery. It is very convenient for outdoor use and on business trip.

⑩Four-hour battery operation
Lithium-ion battery MB400 (option) fully charged enables about four-hour battery operation at backlight off.

⑪Data storage into USB memory
USB memory can be used as an external memory. The screen image is stored by BMP format. And the spectrum waveform, IQ data and setting parameters are stored by CSV format. Moreover, the screen image is copied on the optional USB printer as it is.

⑫Functions comparable to a bench type
・Measuring functions:Channel power, Adjacent channel power, Occupied bandwidth, Electric field strength, Magnetic field strength and Noise measurement
・Calculation functions:MaxHold, MinHold, Averaging, OverWrite
・Marker measurement and peak search function